Power Transformers (up to 110 kV)

Oil-immersed power transformers up to 31,500 kVA and 110 kV class with on-load or off-circuit tap changers for utility substations, solar and wind plants.

16 products

Power-class transformers step a transmission or sub-transmission voltage down to distribution level — or step solar and wind output up for export. Millenium builds three-phase oil-immersed units from 2,000 kVA to 31,500 kVA at 33, 35, 66, 69, 72.5 and 110/115 kV, with on-load tap changers, ONAN/ONAF cooling, conservator and Buchholz protection, and oil, winding and gas monitoring.

Each transformer is designed against the customer's single-line diagram and fault-level study, routine-tested to IEC 60076 and — where the project calls for it — temperature-rise and impulse type-tested with customer or third-party witnesses present.

Power Transformers (up to 110 kV) — product list

Guides and project references for power transformers

Oil-immersed power transformer positioned on a concrete plinth at the substation
🇰🇪 Kenya · Delivered 2023

Kenya: 33 kV/11 kV Distribution Substation

33 kV/11 kV distribution substation — transformer, RMU, LV switchgear, power distribution cabinets and related accessories — Urban and peri-urban…

Read the project sheet →
Contact sheet illustrating four stages of a grid transformer installation: heavy transport, radiator assembly and placement, bushing and auxiliary work, finished bay
🇪🇬 Egypt · Reference design

Egypt: 66 kV/11 kV Oil-Immersed Grid Transformer

66 kV/11 kV oil-immersed grid transformer with radiator cooling and on-load tap changer — Utility transmission and distribution substation, desert…

Read the project sheet →

Power Transformers — frequently asked questions

What is the largest transformer Millenium manufactures?

Power transformers up to 31,500 kVA at 110 kV class, with on-load tap changers and ONAN/ONAF cooling, for utility substations and renewable-energy step-up duty.

Do you offer on-load tap changers?

Yes. OLTC units regulate the secondary voltage while the transformer stays energised and under load; off-circuit tap changers are fitted where manual, de-energised adjustment is sufficient.

Which tests are performed on a power transformer before shipment?

All IEC 60076-1 routine tests — winding resistance, ratio and vector group, impedance and load loss, no-load loss and current, applied and induced voltage, and partial discharge — plus temperature-rise and lightning-impulse type tests on request.

Can’t find the exact rating?

The catalogue shows typical configurations. Every product is built to order — send your single-line diagram or spec and we will quote the exact unit.